A Rhino management sub task for configuring a rate limiter.

Ant Parameters
Attribute Description Required

failonerror

Flag to control failure behaviour. If 'true', the sub task will throw a BuildException when an error is encountered. If 'false', the sub task will throw a NonFatalBuildException instead of a BuildException under specific circumstances. See below for conditions (if any) which will cause a NonFatalBuildException.

No. default value is taken from the Rhino management parent task.

name

The name of the rate limiter to be configured.

Yes.

maxrate

The maximum rate of tokens per second the rate limiter will allow. A value of '-' may be used to clear existing per-node settings when a list of nodes is specified.

No.

bypassed

Whether this rate limiter will be used or bypassed for limiting rate. If false the limiter will be used (not bypassed), if true the limiter will be bypassed and hence not be used. A value of '-' may be used to clear existing per-node settings when a list of nodes is specified.

No.

timeunit

The rate limiter will allow maxrate tokens per timeunit. Allowed values are SECONDS, MINUTES, HOURS, DAYS.

No.

depth

Controls the amount of "burstiness" allowed by the rate limiter. A value of '-' may be used to clear existing per-node settings when a list of nodes is specified.

No.

parent

Sets the parent of the limiter, adding the limiter to its parent’s limiter hierarchy.

No.

nodes

Comma-delimited list of nodes to apply this configuration to. Only the maxrate, bypassed, and depth configuration properties may be set on a per-node basis, all other properties are set uniformly across all nodes.

No.

Previous page Next page