Context

The context of rewriters list within the schema tree is shown. Italicised links are to other pages.

The rules specifying which SCCP address parameters to alter when this replace-gt rule is activated.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

List Structure

id string
addrinfo string
gtencoding uint8
gti uint8
natofaddr uint8
numplan uint8
route-on enumeration
ssn uint8
trtype uint8

The key is id.

id

Identifier used to reference this replace-gt rule in outbound and inbound translations.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

This node is mandatory.

Type string

Value

a string

addrinfo

The replacement address digits.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

Type string

Value

a string

gtencoding

The replacement GT encoding.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

Type uint8

Value

a number in the range 0 or more

gti

The replacement global title indicator.

ITU-T SCCP valid values: 1-4.

ANSI SCCP valid values: 1-2.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

Type uint8

Value

a number in the range 0 or more

natofaddr

The replacement nature of address.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

Type uint8

Value

a number in the range 0 or more

numplan

The replacement numbering plan.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

Type uint8

Value

a number in the range 0 or more

route-on

The action to perform on the routing indicator when this replace-gt rule is activated.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

Type enumeration

Value

one of the following

Value Description

SSN

Set to route on Sub-System Number (SSN).

GT

Set to route on Global Title (GT).

RI

Leave the routing indicator unchanged.

ssn

The replacement SSN.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

Type uint8

Value

a number in the range 0 or more

trtype

The replacement translation type.

Warning

See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value.

Type uint8

Value

a number in the range 0 or more

Previous page Next page
Rhino VoLTE TAS Version 4.1