Context
The context of rewriters list
within the schema tree is shown. Italicised links are to other pages.
deployment-config:sgc (in sgc-config.yaml) m3ua global-title outbound rewriters list id addrinfo gtencoding gti natofaddr numplan route-on ssn trtype
The rules specifying which SCCP address parameters to alter when this replace-gt rule is activated.
See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value. |
id
Identifier used to reference this replace-gt rule in outbound and inbound translations.
See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value. |
This node is mandatory.
Type string
- Value
-
a string
gtencoding
The replacement GT encoding.
See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value. |
Type uint8
- Value
-
a number in the range 0 or more
gti
The replacement global title indicator.
ITU-T SCCP valid values: 1-4.
ANSI SCCP valid values: 1-2.
See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value. |
Type uint8
- Value
-
a number in the range 0 or more
route-on
The action to perform on the routing indicator when this replace-gt rule is activated.
See 'Reconfiguring the SGC' in 'Rhino VoLTE TAS Configuration and Management Guide' for how to activate changes to this value. |
Type enumeration
- Value
-
one of the following
Value | Description |
---|---|
|
Set to route on Sub-System Number (SSN). |
|
Set to route on Global Title (GT). |
|
Leave the routing indicator unchanged. |