The SS7 SGC Stack acts as one or more Application Servers when connected to the Signalling Gateway or another Application Server (in IPSP mode). M3UA configuration can be separated into two related domains:

Note
Attribute modification restrictions

Only attributes that are "Reconfigurable" can be modified after a configuration object is created. Attributes that do not support "Active Reconfiguration" can be changed only when the configuration object is disabled (the value of its disabled attribute is false).

Application Server and routes

After an SCTP association with SG is established, the as-connection that maps connections to Application Servers is checked. This allows for the SGC to inform SG which routing contexts should be active for that SCTP association. Also, with mapping internally, SGC decides which Point Codes are reachable through the SCTP association (the chain of dependencies is: connection - as-connection - as - route - pc).

as

Represents an Application Server — a logical entity serving a specific Routing Key. Defines the Application Server that the SGC Stack will represent after the connection to SG/IPSP peer is established.

Attribute name
Attribute description Default Modification

oname

object name

dependencies

number of items which depend on this object

Read-only

enabled

is object enabled

false

Reconfigurable using active reconfiguration

traffic-maintenance-role

what kind of AS this is; whether it should handle
sending (ACTIVE) or reception (PASSIVE) of ASP_(IN)ACTIVE

ACTIVE

rc

routing context NOTE: This attribute is optional, but only one as with an unspecified rc can be used per association.

state

state of the AS (DOWN, PENDING, ACTIVE, INACTIVE).

Read-only

pending-size

maximum number of pending messages, per node

Applicable only to AS mode.

0

Reconfigurable

pending-time

maximum pending time (in milliseconds)

Applicable only to AS mode.

0

Reconfigurable

Note The JMX Object name for as is SGC:type=m3ua,category=as.

route

Mapping of DPCs (dpc) accessible when a particular Application Server (as) is active.

Attribute name Attribute description Default Modification

oname

object name

dependencies

number of items which depend on this object

Read-only

dpc-name

reference to DPC

as-name

reference to AS

priority

priority of the route (larger value is higher priority)

0

Note The JMX Object name for route is SGC:type=m3ua,category=route.

dpc

A DPC defines a remote point code which is accessible from this SGC cluster. DPCs are used to define routes (route) which bind DPCs to specific Applications Server (as) definitions and SCTP associations (connections).

Attribute name Attribute description Default Modification

oname

object name

dependencies

number of items which depend on this object

Read-only

dpc

destination point code; format dependent on sccp-variant configuration:

  • ITU; a 14-bit integer; supported formats: simple integer (4106) or int(3bit)-int(8bit)-int(3bit) (2-1-2)

  • ANSI; a 24-bit integer; supported formats: simple integer (34871) or int(8bit)-int(8bit)-int(8bit) in Network-Cluster-member order (3-125-44). This simple integer is the network byte order integer derived from the ANSI MTP/M3UA transmission order of the network, cluster and member components. i.e. [00000000 NNNNNNNN CCCCCCCC MMMMMMMM]

Reconfigurable

na

network appearance

Attribute is optional

Reconfigurable

mss

maximum user data length per segment to send to this destination, supported values are sccp-variant dependent:

  • ITU: 0-247 (0=do not segment)

  • ANSI: 0-245 (0=do not segment)

245

Reconfigurable

muss

maximum unsegmented SCCP message size to send to this destination as a single unsegmented message, supported values are sccp-variant dependent:

  • ITU: 160-254 inclusive

  • ANSI: 160-252 inclusive

252

Reconfigurable

pudt

SCCP message type that this destination prefers to receive when there is a choice available, supported values: UDT, XUDT

UDT

Reconfigurable

congestion-notification-timeout

ANSI SCCP only: the time in milliseconds for which a congestion notification from M3UA should be considered valid. Supported values: 0+ (0=disable)

600000

Reconfigurable

Note The JMX Object name for dpc is SGC:type=m3ua,category=dpc.

as-precond

Before the Application Server (as) becomes active, the SGC Stack may require certain TCAP Stacks representing some SSN (CGIN RAs) to register with SGC. The Application Server will be activated after ALL defined preconditions (as-precond) are satisfied.

Attribute name Attribute description Default Modification

oname

object name

dependencies

number of items which depend on this object

Read-only

as-name

affected AS name

ssn

subsystem number which must be connected

Note The JMX Object name for as-precond is SGC:type=m3ua,category=as-precond.

as-connection

Mapping of Application Server (as) to SCTP association (connection), defining which Application Servers should be active on a particular connection.

Attribute name Attribute description Default Modification

oname

object name

dependencies

number of items which depend on this object

Read-only

as-name

reference to AS

conn-name

reference to SGConnection

daud-on-asp-ac

sending DAUD on asp-active

true

Reconfigurable

Note The JMX Object name for as-connection is SGC:type=m3ua,category=as-connection.

Listening for and establishing SCTP associations

Below are attributes for configuration directly related to establishing SCTP associations to M3UA peers.

local-endpoint

local-endpoint, together with local-endpoint-ip, defines the IP address where the SGC Node should listen for incoming SCTP associations.local-endpoint configuration is also used as the source address for outgoing SCTP associations. local-endpoint by itself defines the port and M3UA configuration for all connections that are associated with it.

Note Each SGC Node can use multiple local endpoints.
Attribute name Attribute description Default Modification

oname

object name

dependencies

number of items which depend on this object

Read-only

enabled

is object enabled

false

Reconfigurable using active reconfiguration

active

is object active

Read-only

node

SGC Node where the object is used

port

local SCTP port

Reconfigurable

max-in-streams

maximum number of input streams requested by the local endpoint
during association initialization

OS default

Reconfigurable

max-out-streams

maximum number of output streams requested by the local endpoint
during association initialization

OS default

Reconfigurable

so-sndbuf

size of the socket send buffer

OS default

Reconfigurable

so-rcvbuf

size of the socket receive buffer

OS default

Reconfigurable

max-asp-active-count

maximum asp-active sending count

100

Reconfigurable

max-asp-inactive-count

maximum asp-inactive sending count

100

Reconfigurable

max-asp-up-count

maximum asp-up sending count

100

Reconfigurable

max-asp-down-count

maximum asp-down sending count

100

Reconfigurable

no-delay

enables or disables a Nagle-like algorithm

true

Reconfigurable

so-linger

linger on close if data is present

OS default

Reconfigurable

Note The JMX Object name for local-endpoint is SGC:type=m3ua,category=local-endpoint.

local-endpoint-ip

Configuration of IPs for local-endpoint, to make use of SCTP multi-homed, feature-defined, multiple IPs for a single local endpoint.

Attribute name Attribute description Default Modification

oname

object name

dependencies

number of items which depend on this object

Read-only

ip

IPv4 or IPv6 address

local-endpoint-name

name of the referenced local endpoint

Note The JMX Object name for local-endpoint-ip is SGC:type=m3ua,category=local-endpoint-ip.
Tip
IPv6 considerations

When using IPv6 addressing, remember to configure the PREFER_IPV4 property in the sgcenv file.
For details, please see configuring SGC_HOME/config/sgcenv

connection

connection, together with conn-ip, defines the remote IP address of the SCTP association. The SGC Node will either try to establish that association (CLIENT mode) or expect a connection attempt from a remote peer (SERVER mode).

Attribute name Attribute description Default Modification

oname

object name

dependencies

number of items which depend on this object

Read-only

enabled

is object enabled

false

Reconfigurable using active reconfiguration

active

is object active

Read-only

port

remote SCTP port

Reconfigurable

local-endpoint-name

reference name to local endpoint

conn-type

specifies if acts as server for SCTP connect (CLIENT/SERVER)

Reconfigurable

t-ack

specifies how often ASP attempts to send AspUP

2

Reconfigurable using active reconfiguration

t-daud

specifies how often ASP attempts to send DAUD

60

Reconfigurable using active reconfiguration

t-reconnect

specifies time interval (in seconds) between connection attempts

6

Reconfigurable using active reconfiguration

state-maintenance-role

specifies whether the SGC will send ASP-UP (ACTIVE) or expects to receive ASP-UP (PASSIVE) on connection establishment.

ACTIVE

Reconfigurable

asp-id

asp identifier

Attribute is optional

Reconfigurable

is-ipsp

specifies whether connection works in IPSP mode

true

out-queue-size

maximum number of messages waiting to be written into the SCTP association

1000

Reconfigurable

Note The JMX Object name for connection is SGC:type=m3ua,category=connection.

conn-ip

Configuration of IPs for connection, to make use of SCTP multi-homed, feature-defined,multiple IPs for a single connection.

Attribute name Attribute description Default Modification

oname

object name

dependencies

number of items which depend on this object

Read-only

ip

IPv4 or IPv6 address

conn-name

name of the referenced connection

Note The JMX Object name for conn-ip is SGC:type=m3ua,category=conn-ip.
Tip
IPv6 considerations

When using IPv6 addressing, remember to configure the PREFER_IPV4 property in the SGC_HOME/config/sgcenv file. For details, please see configuring SGC_HOME/config/sgcenv

Previous page Next page