To get or set the SIP originating macro, use the following sis-console command, Ant task, or related MBean operation:

Note
About the SIP Originating Macro

Unlike IN protocols, SIP has no standard for determining whether an initial request is as an "originating" or "terminating" trigger. This is network-specific.

The SIS needs to know whether the request is originating or terminating when it determines the trigger address tracing selectors for an initial request. The SIS uses a user-defined macro to do this for SIP.

This macro is specified using the commands below. It must return true if an initial request is an originating trigger. If the macro returns false, the SIS treats the request as if it was a terminating trigger. If no originating macro is configured, the SIS treats all initial requests as originating, for the purposes of trigger address tracing.

Tip This is a SIS feature for SIP.

Console commands

getSIPOriginatingMacro

Command

getsiporiginatingmacro <ra-entity>
    Get the currently configured SIP originating macro.

Example

$ sis-console getsiporiginatingmacro sipsis
Current originating macro is MacroID[name=IsOriginating,vendor=OpenCloud,version=1.0]

setSIPOriginatingMacro

Command

setsiporiginatingmacro <ra-entity> <macro-id>
    Set the macro used by trigger address tracing to determine if an initial
    SIP request is originating or terminating.

Example

$ sis-console setsiporiginatingmacro sipsis name=IsOriginating,vendor=OpenCloud,version=1.0
Originating macro set to MacroID[name=IsOriginating,vendor=OpenCloud,version=1.0]

Ant task

setSIPOriginatingMacro

Task

<setsiporiginatingmacro>
    <macro name="..." vendor="..." version="..."/>
</setsiporiginatingmacro>

Example

<sis-sip-management>
    ...
    <setsiporiginatingmacro>
        <macro name="Originating" vendor="XYZ" version="1.1"/>
    </setsiporiginatingmacro>
</sis-sip-management>

MBean operations

MBean

getOriginatingMacro

Operation

public MacroID getOriginatingMacro() throws ManagementException;

setOriginatingMacro

Operation

public void setOriginatingMacro(MacroID id) throws ManagementException;