Application not running after installation

Check that bootstrap and configuration were successful:

[sentinel@custom1 ~]$ grep 'Bootstrap complete' ~/bootstrap/bootstrap.log
2019-10-28 13:53:54,226 INFO bootstrap.main Bootstrap complete
[sentinel@custom1 ~]$

If the bootstrap.log does not contain that string, examine the log for any exceptions or errors.

[sentinel@custom1 ~]$ report-initconf status
status=vm_converged
[sentinel@custom1 ~]$

If the status is different, examine the output from report-initconf for any problems. If that is not sufficient, examine the ~/initconf/initconf.log file for any exceptions or errors.

If bootstrap and configuration were successful, check the Rhino journalctl logs.

[sentinel@custom1 ~]$ journalctl -u rhino -l

Further information can also be found from the MCP logs in /var/log/tas and its subdirectories.

Bootstrap and/or initconf failures are often caused by networking issues.

  • Check that each VM can ping all of the:

    • other signaling IPs of VMs with the same node type

    • TSN signaling IPs.

Previous page Next page
MCP VM Configuration Guide Version 1.5